Frequently Asked Questions & Trouble Shooting
Q: Do your chargers have any fault code indications that may appear if there is a problem with my charger or my batteries?
A: Yes, beginning in 2007, all Pro, SE, and XL Series chargers have been equipped with the capability of displaying fault codes. Listed below are the possible fault conditions and what they mean: (These fault codes are also present on all Eagle Series chargers)
RED BLINKING LED………….NO BATTERY DETECTEDThis indication occurs whenever the charger circuitry cannot detect a battery. The charger circuitry will not allow charge current to flow under this condition. With the AC power supply cord unplugged, check the connection to the batteries for proper polarity (black wire to negative or -). Also check for corrosion free secure connections to the battery. Please call the factory at 1-800-742-2740 for further assistance.
2 RED BLINKING LEDS………..FORMING STAGE TIMEOUT SHUTDOWNThis indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first 3 hours of charging. This indicates a possible battery problem and the charge cycle has been terminated at this point. The charger may be reset by disconnecting and reconnecting the AC power supply cord. Please call the factory at 1-800-742-2740 for further assistance.
3 RED BLINKING LEDS………..OVERALL TIMER SHUTDOWNThis indication occurs if the charger has not completed the charge cycle within the allowable factory set time period. This indicates a possible battery problem and the charge cycle has been terminated at this point. The charger may be reset by disconnecting and reconnecting the AC power supply cord. Please call the factory at 1-800-742-2740 for further assistance.
4 RED BLINKING LEDS………..INTERNAL OVERTEMP SHUTDOWNThis indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are above factory specified levels. This could indicate a possible charger problem and the charge cycle has been terminated. The charger may be reset by disconnecting and reconnecting the AC power supply cord. Please call the factory at 1-800-742-2740 for further assistance.
5 RED BLINKING LEDS………..OVERVOLTAGE PROTECTIONThis indication occurs if the charger circuitry has detected that the output circuitry is possibly defective. Please discontinue use of the charger and call the factory at 1-800-742-2740.