Use Precautions of Pipette - Hawach (2024)

Skip to content

+86-29-89284429

pipette@hawach.com

It is very crucial to correctly and properly use the pipette, which is worthy of being paid great attention to by the operators. To prevent pipette damage and personal injury, learning about the use of precautions is very necessary. The following precautions should be taken when using Advanced Fully Autoclave Single-Channel Fixed Pipettes, Advanced Half Autoclave Single Channel Fixed Pipettes, Standard Single Channel Fixed Pipettes, Electronic Control Digital Pipettes, Advanced Half Autoclave Single Channel Fixed Pipettes.

Pipetting Precaution

First of all, remember do not pipette if the tip is not installed. At the beginning of the sample pipettingoperation, it is necessary tokeep it slow and stableby preventingthe samplefrom entering the solutionextractor, in case of the occurrence of air leakagedue to the excessive speed. To obtain high precision, it is essential to extract the sample solutiononce before the formal pipetting, especially whendealing withthe serum protein solution or organic solvent.

It is possible to forma “liquid film” on the inner wall, which wouldcauseasmalldrainage volume. In particular, it is strictly forbidden to extractsolutions with strong volatility and strong corrosiveness, such as concentrated acid andalkaline.

Use Precautions of Pipette - Hawach (3)

Use Precautions of Pipette - Hawach (4)

Use Precautions of Pipette - Hawach (5)

1. Aspiration and drainage
Vertical aspiration; the tip of the tip is immersed in the liquid surface below 3mm. The tip of the tip is pre-flushed in the liquid before the aspiration; slow suction and slow release; if the amount is small when the liquid is discharged, the tip of the tip should be the inner wall of the container.

2. Pipette placement
Pipettes that hold liquid should not lay flat, and the liquid inside the tip can easily contaminate the inside of the gun and may cause the spring of the gun to rust. If the pipette is not in use, it is recommended to hang it vertically on the pipette holder. The product should be adjusted to maximum after each experiment, allowing the spring to return to the prototype to extend the life of the pipette.

3. When sucking the liquid, be sure to release the thumb slowly and smoothly. Never let it suddenly loosen, in case the solution is sucked too fast and flushed into the pipette of the pipette to corrode the plunger and cause air leakage.

4. In order to obtain higher precision, the sample solution needs to be sucked once before the sample is taken, and then the liquid is officially pipetted. When the serum protein solution or the organic solvent is taken up, a “liquid film” remains on the inner wall of the tip, causing the liquid discharge amount. It is too small and produces errors.

Other Precautions

Check for leakageduring the useof a pipette. The method is to extract the solution and put it vertically for a few seconds to observe whether thesolutionlevel has dropped.Also, make sure the pipette can adapt to high temperatures before being autoclaved.

qoybr2023-07-12T02:42:36+00:00July 12th, 2023|

Share This Story, Choose Your Platform!

Related Posts

Page load link
Go to Top
Use Precautions of Pipette - Hawach (2024)
Top Articles
How Long Does it Take for a Check to Clear? | Chase
Safeway Mobile App Frequently Asked Questions
Noaa Charleston Wv
Mychart Mercy Lutherville
Steamy Afternoon With Handsome Fernando
Beds From Rent-A-Center
Okatee River Farms
Bhad Bhabie Shares Footage Of Her Child's Father Beating Her Up, Wants Him To 'Get Help'
Meg 2: The Trench Showtimes Near Phoenix Theatres Laurel Park
Bustle Daily Horoscope
Spelunking The Den Wow
Immediate Action Pathfinder
Wordle auf Deutsch - Wordle mit Deutschen Wörtern Spielen
Painting Jobs Craigslist
Amc Flight Schedule
Swedestats
Gemita Alvarez Desnuda
Best Uf Sororities
Video shows two planes collide while taxiing at airport | CNN
Schedule 360 Albertsons
Tinker Repo
The Weather Channel Local Weather Forecast
Dewalt vs Milwaukee: Comparing Top Power Tool Brands - EXTOL
Www Va Lottery Com Result
Gotcha Rva 2022
3 2Nd Ave
Water Temperature Robert Moses
800-695-2780
Schooology Fcps
Ipcam Telegram Group
Rays Salary Cap
Craigslist Sf Garage Sales
Angel del Villar Net Worth | Wife
Fairwinds Shred Fest 2023
Otis Offender Michigan
Royals op zondag - "Een advertentie voor Center Parcs" of wat moeten we denken van de laatste video van prinses Kate?
Dallas City Council Agenda
Emerge Ortho Kronos
Dmitri Wartranslated
Stafford Rotoworld
18 terrible things that happened on Friday the 13th
Best Restaurants West Bend
Tricia Vacanti Obituary
Subdomain Finder
Chase Bank Zip Code
Cara Corcione Obituary
Google Flights Missoula
Hampton Inn Corbin Ky Bed Bugs
Arnold Swansinger Family
Fahrpläne, Preise und Anbieter von Bookaway
7 Sites to Identify the Owner of a Phone Number
Cbs Scores Mlb
Latest Posts
Article information

Author: Wyatt Volkman LLD

Last Updated:

Views: 5969

Rating: 4.6 / 5 (66 voted)

Reviews: 89% of readers found this page helpful

Author information

Name: Wyatt Volkman LLD

Birthday: 1992-02-16

Address: Suite 851 78549 Lubowitz Well, Wardside, TX 98080-8615

Phone: +67618977178100

Job: Manufacturing Director

Hobby: Running, Mountaineering, Inline skating, Writing, Baton twirling, Computer programming, Stone skipping

Introduction: My name is Wyatt Volkman LLD, I am a handsome, rich, comfortable, lively, zealous, graceful, gifted person who loves writing and wants to share my knowledge and understanding with you.