Ismael Cordero

Although we often think of fuses as a nuisance, they play an important safety role in preventing damage to equipment due to electrical overloading, thereby reducing the risk of electrical shock to patients and staff. You should not dismiss a blown fuse as an inconvenience. It may be a sign that a real fault has developed, giving you the chance to find and fix the problem before any serious damage occurs.

Fuses degrade with time and will eventually fail. A blown fuse does not always mean that there is something wrong with the equipment, and in this article we will show you how to replace such a fuse.

However, do not keep replacing a fuse if it blows immediately after you replace it. In these instances, call a qualified biomedical equipment technician to service the equipment.

A fuse is essentially a short piece of wire of a selected diameter and composition so that it conducts current up to a certain level, but melts or ‘fuses’ if the current rises above that level. It becomes an open circuit when it blows, interrupting the flow of current and preventing damage.

In most cases, the fuse wire is mounted inside a small glass or ceramic tube, fitted with metal end caps. The glass tube forms a physical guard for the fuse, so that when it blows the molten metal does not cause damage or injury. A glass tube allows you to see when the fuse has blown: there will be a gap in the wire or a metallic smear on the inside of the glass.

Procedure

Many electrical devices used in eye care have an externally accessible fuse near the electrical cord (Figure 1) that you can check and replace by following these steps.

  1. Disconnect the device from the electrical system.

  2. Remove the fuse from its holder. In some cases you may need a small screwdriver to unscrew the fuse holder cap.

  3. Look at the fuse wire. If there is a visible gap in the wire or a dark or metallic smear inside the glass then the fuse is blown and needs to be replaced. If you cannot see whether the fuse is blown, follow steps 4 and 5. If the fuse is definitely blown, go to step 6.

  4. Set a multimeter (Figure 2) to the resistance or Ω (Ohms) setting.

    Open in a separate window

    Figure 2.

  5. Place one of the multimeter leads on one end of the fuse. Place the other lead on the other end of the fuse. If the reading is between 0 and 5 Ω (Ohms), the fuse is good. A higher reading indicates a bad or degraded fuse. A reading of OL (Over Limit) definitely means a blown fuse.

  6. If the fuse is blown, replace the fuse with one that is exactly the same (see panel). Make sure to note the fuse amperage and voltage ratings, which should be marked on the fuse itself (Figure 3) or on the panel label near the fuse holder. Additionally, note the size and whether it is a slow-blow or a fast-blow type fuse. If there are no markings on the fuse itself or on the equipment you must consult the device's operating manual.

    Open in a separate window

    Figure 3.

    Types of fuses

General suggestions

  • Always disconnect equipment from electrical power before removing a fuse; not doing so may result in serious injury.

  • Always replace a fuse with an identical type, and never substitute a fuse with foil or another object. This could lead to electrocution and fires.

  • Keep enough stock of the fuses used in your clinic or hospital. Store each type in separate containers with a label describing the fuse's voltage and amperage, whether it is a fast-blow or slow-blow type, the size, minimum number needed (the minimum stock level), and the models of equipment that use each type of fuse.

  • Check your stock of fuses frequently and order more fuses when it reaches the minimum stock level.

  • If possible, tape a spare fuse to the equipment so that it is available when needed.

More about fuses

You should note the following when replacing fuses to ensure an exact match.

Amperage rating (A). This indicates how much current the fuse can carry. Most eye care devices have fuses rated between 0 and 10 amperes.

Voltage rating (V). This is the maximum supply voltage that the fuse can safely carry. The most popular ratings are 125V and 250V.

Blowing type. Fast-blow fuses will blow as soon as the current reaches the fuse's amperage rating, while slow-blow fuses are designed to tolerate a large number of startup surges and modest short-term overloads without blowing. Fast-blow fuses usually have a thin wire while slow-blow fuses usually have a thicker, coiled wire. You should never substitute a slow-blow fuse for a fast-blow fuse or vice versa.

Size and tube material. Most fuses used in medical equipment have a glass tube but you may find some with ceramic tubes. The two most common sizes of fuses are:

  • American size: 3.2 cm × 0.6 cm (¼ inches × ¼ inch),

  • European size: 20 mm × 5 mm (0.8 inches × 0.2 inches).

Articles from Community Eye Health are provided here courtesy of International Centre for Eye Health

Checking and replacing fuses (2024)
Top Articles
4 B2B Stories We Can Learn From
25 Top Penetration Testing Tools for Kali Linux in 2024
Stephanie Miller Net Worth
Virtual Prepaid Minutes
Stcloudcraigslist
Weve Got You Surrounded Meme
Christine Paduch Howell Nj
Shemales In Irvine
What I did for an A, by sena1989
Shoplyfter Dressed For The Occasion
Ksp Er-7500
Gpa Calculator Georgia Tech
Jug Cousin Crossword Clue
Loss Payee And Lienholder Addresses And Contact Information Updated Daily Free List Bank Of America
Pedicuresnear Me
Pet Friendly Apartments for Rent in Phoenix, AZ - 2,179 Rentals | Zumper
12 Craigslist alternatives to sell stuff, find a job, or get laid
Ninjago Deviantart
My Struggle Boosie Movie Hulu
Desert Cabinet Odds And Ends
Sprinter Tyrone's Unblocked Games
Town History - Waltham Abbey
Teenlilyrose08
Byui Graduation Spring 2023
Musc Children's Health After Hours Care - North Charleston
The Best Online Pharmacies in Kenya - The Best in Kenya
BWW Interview: Marilu Henner Talks THE MARILU HENNER SHOW, Her Highly Superior Autobiographical Memory & More!
Julez Garcia Ogden Utah
Jamie Soricelli Friend Kelly Courtney
Craigslist Pets Seattle Tacoma Washington
Magma Lozenge Location
Express Employment Sign In
Hillside Funeral Home Washington Nc Obituaries
The Creator Showtimes Near Amc Madison Yards 8
The News and Herald from Winnsboro, South Carolina
Amy Riley Electric Video
Nepg Live Scoring
T&G Pallet Liquidation
Olde Kegg Bar & Grill Portage Menu
Dirtyone 2006
Remax Mls
Craigslist Rentals Coquille Oregon
O'reilly's Lee Road
Quest Diagnostics Mt Morris Appointment
Yellow Sun Of Ecuador by The Classics
Pizza Hut Doordash Promo Code
Pg Thomasson Funeral Services Obituaries
The Leaf-Chronicle from Clarksville, Tennessee
Movierulz Plz 3
Topeka Pets Craigslist
Latest Posts
Article information

Author: Stevie Stamm

Last Updated:

Views: 6254

Rating: 5 / 5 (60 voted)

Reviews: 91% of readers found this page helpful

Author information

Name: Stevie Stamm

Birthday: 1996-06-22

Address: Apt. 419 4200 Sipes Estate, East Delmerview, WY 05617

Phone: +342332224300

Job: Future Advertising Analyst

Hobby: Leather crafting, Puzzles, Leather crafting, scrapbook, Urban exploration, Cabaret, Skateboarding

Introduction: My name is Stevie Stamm, I am a colorful, sparkling, splendid, vast, open, hilarious, tender person who loves writing and wants to share my knowledge and understanding with you.